https://www.science.org/doi/10.1126/sciadv.adh8263
QT:{{”
Many volatile organic compounds (VOCs) persisted days following the smoke injection, providing a longer-term exposure pathway for humans….These rates imply that vapor pressure controls partitioning behavior and that house ventilation plays a minor role in removing smoke VOCs. However, surface cleaning activities (vacuuming, mopping, and dusting) physically removed surface reservoirs and thus reduced indoor smoke VOC concentrations more effectively than portable air cleaners and more persistently than window opening.
“}}